Synergy Software Package User's Manual
|
The CAN HAL module provides a high-level API for CAN network applications and supports the CAN peripherals available on the Synergy microcontroller hardware. A user-callback function must be defined, which the driver will invoke when transmit, receive or error interrupts are received. The callback returns with a parameter which indicates the channel, mailbox and event.
The following hardware features are, or are not, supported by SSP for CAN:
Legend:
| Symbol | Meaning |
|---|---|
| ✓ | Available (Tested) |
| ⌧ | Not Available (Not tested/not functional or both) |
| N/A | Not supported by MCU |
| MCU Group | Programmable Bit Rate | Support up to 32 Mailboxes | Mailbox Normal Mode | Mailbox FIFO Mode | Support for Data Frame Reception | Support for Remote Frame Reception |
|---|---|---|---|---|---|---|
| S124 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S128 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S1JA | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S3A1 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S3A3 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S3A6 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S3A7 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S5D3 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S5D5 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S5D9 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| S7G2 | ✓ | ✓ | ✓ | ⌧ | ✓ | ✓ |
| MCU Group | Programmable one-shot reception | Overwrite mode reception | Overrun mode reception | Support all 8 Acceptance Masks | Support Masks independently enabled or disabled for each Mailbox |
|---|---|---|---|---|---|
| S124 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S128 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S1JA | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S3A1 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S3A3 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S3A6 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S3A7 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S5D3 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S5D5 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S5D9 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| S7G2 | ⌧ | ✓ | ✓ | ✓ | ✓ |
| MCU Group | Support for transmission request abort | Mode transition for bus-off: ISO11898-1 specification -compliant | Mode transition for bus-off: Automatic invoking of CAN halt mode on bus-off entry | Mode transition for bus-off: Automatic invoking of CAN halt mode on bus-off end | Mode transition for bus-off: Invoking of CAN halt mode through software | Mode transition for bus-off: Transition to error active state through software. |
|---|---|---|---|---|---|---|
| S124 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S128 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S1JA | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S3A1 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S3A3 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S3A6 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S3A7 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S5D3 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S5D5 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S5D9 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| S7G2 | ⌧ | ✓ | ⌧ | ⌧ | ⌧ | ⌧ |
| MCU Group | Monitoring of all CAN bus errors {Stuff, Form, ACK, 15-bit CRC, Bit error, ACK Delimiter} | Detection of all transition to error states {error warning, error passive, bus-off entry, and bus-off Recovery} | Support Interrupt Sources {Receive FIFO, Transmit FIFO } | Support Interrupt Sources {Reception complete. Transmission complete, Error interrupts} | Support CAN sleep mode 1 {stop CAN clock} | Support all 3 software units {Acceptance filter support, Mailbox search support, including receive mailbox search, transmit mailbox search, and message lost Search, Channel search support} |
|---|---|---|---|---|---|---|
| S124 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S128 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S1JA | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S3A1 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S3A3 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S3A6 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S3A7 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S5D3 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S5D5 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S5D9 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| S7G2 | ✓ | ✓ | ⌧ | ✓ | ✓ | ✓ |
| MCU Group | CAN Source Clock: PCLKB | CAN Source Clock: CANMCLK | Support all 3 Test Modes {Listen-only, Self-Test 1 (external loopback), Self Test 2 (internal loopback)} | Module-stop Function | Support Standard CAN (11 bit) | Support Extended CAN (29 bit) |
|---|---|---|---|---|---|---|
| S124 | N/A | ✓ | ✓ | ✓ | ✓ | ✓ |
| S128 | N/A | ✓ | ✓ | ✓ | ✓ | ✓ |
| S1JA | N/A | ✓ | ✓ | ✓ | ✓ | ✓ |
| S3A1 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| S3A3 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| S3A6 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| S3A7 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| S5D3 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| S5D5 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| S5D9 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| S7G2 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
The CAN HAL defines APIs for opening, closing, writing (transmitting) and reading (receiving) CAN data; it also provides some additional functions to assist in processing more complex commands. A complete list of the available APIs, an example API call and a short description of each can be found in the following table. A table of status return values follows the API summary table.
CAN HAL Module API Summary
| Function Name | Example API Call and Description |
|---|---|
| open | g_can0.p_api->open(g_can0.p_ctrl, g_can0.p_cfg)The open API configures CAN Channel 0. This function must be called before any other CAN functions.Note: This call is made automatically during system initialization, prior to entering the users thread. Unless the user closes the module, open will not need to be called. |
| close | g_can0.p_api->close(g_can0.p_ctrl)The close API handles the clean-up of internal driver data. |
| read | g_can0.p_api->read (g_can0.p_ctrl, p_args->mailbox, &receiveFrame)The read API reads received CAN data. |
| write | g_can0.p_api->write (g_can0.p_ctrl, 0, &transmitFrame)The write API write data into the CAN transmit frame buffer and send it out. |
| control | g_can0.p_api->control(g_can0.p_ctrl, CAN_COMMAND_MODE_SWITCH, &mode);with can_mode_t mode = CAN_MODE_LOOPBACK_INTERNAL;The control API will be able to change the CAN mode of operation. |
| infoGet | g_can0.p_api->infoGet(g_can0.p_ctrl, p_info)The infoGet API retrieves the CAN mode of operation. |
| versionGet | g_can0.p_api->versionGet(version)The versionGet API retrieves the module version information. |
Status Return Values
| Name | Description |
|---|---|
| SSP_SUCCESS | API Call Successful. |
| SSP_ERR_INVALID_ARGUMENT | Parameter has invalid value. |
| SSP_ERR_HW_LOCKED | Lock already owned by another user. |
| SSP_ERR_CAN_MODE_SWITCH_FAILED | Channel failed to switch modes. |
| SSP_ERR_CAN_INIT_FAILED | Channel failed to initialize. |
| SSP_ERR_ASSERTION | Null pointer presented. |
| SSP_ERR_NOT_OPEN | Port is not open. |
| SSP_ERR_CAN_DATA_UNAVAILABLE | No data available. |
| SSP_ERR_CAN_TRANSMIT_MAILBOX | Mailbox is not setup for receive. |
| SSP_ERR_CAN_TRANSMIT_NOT_READY | Transmit in progress, cannot write data at this time. |
| SSP_ERR_CAN_RECEIVE_MAILBOX | Mailbox is setup for receive and cannot send. |
The CAN HAL module controls the CAN peripherals on Synergy microcontrollers according to the user configuration. The API provides open, close, read, write, control and information functions. The driver allows for bit-timing configuration as defined in the CAN specification; it can be configured for up to 32 transmit or receive mailboxes with standard or extended ID frames. Receive mailboxes can be configured to capture either data or remote CAN frames. The user callback is invoked with the channel, mailbox and event information when a transmit, receive or error interrupt occurs.
Using the CAN IDs and Masks
Each CAN Mailbox configured to receive messages has an ID and Mask set. Incoming messages will be placed in the lowest mailbox where the following is true:
Incoming ID & Mailbox Mask == Mailbox ID & Mailbox Mask
Example 1: A mailbox with an ID of 0x25 and a mask of 0x1FFFFFFF can receive messages with IDs of 0x25.
Example 2: A mailbox with an ID of 0x25 and a mask of 0x1FFFFFF0 can receive messages with IDs of 0x20 through 0x2F.
Using the CAN HAL Module Test Modes
The CAN Module has three test modes, listen only, external loopback and internal loopback.
Changing the CAN HAL Module Operating Modes
The CAN Module can be switched between modes using the can_api_t::control API. Pass CAN_COMMAND_MODE_SWITCH and a pointer to a can_mode_t variable set to the desired mode into the can_api_t::control API.
| Mode | can_mode_t value | Reason for use |
|---|---|---|
| Normal | CAN_MODE_NORMAL | Normal operation mode |
| Internal Loopback | CAN_MODE_LOOPBACK_INTERNAL | Internal loopback testing |
| External Loopback | CAN_MODE_LOOPBACK_EXTERNAL | External loopback testing |
| Listen Only | CAN_MODE_LISTEN | Baud rate detection |
| Halt | CAN_MODE_HALT | Mailbox configuration and test mode setting |
| Sleep | CAN_MODE_SLEEP | Stops the clock supply to the CAN module reducing current consumption |
| Exit Sleep | CAN_MODE_EXIT_SLEEP | Internal use only |
| Reset | CAN_MODE_RESET | Communication configuration |
Example usage:
This section describes how to include the CAN HAL Module in an application using the SSP configurator.
To add the CAN Driver to an application, simply add it to a thread using the stacks selection sequence given in the following table. (The default name for the CAN Driver is g_can0. This name can be changed in the associated Properties window.)
CAN HAL Module Selection Sequence
| Resource | ISDE Tab | Stacks Selection Sequence |
|---|---|---|
| g_can0 CAN Driver on r_can | Threads | New Stack> Driver> Connectivity> CAN Driver on r_can |
When the CAN Driver on r_can is added to the thread stack as shown in the following figure, the configurator automatically adds any needed lower‑level modules. Any modules needing additional configuration information have the box text highlighted in Red. Modules with a Gray band are individual modules that stand alone. Modules with a Blue band are shared or common; they need only be added once and can be used by multiple stacks. Modules with a Pink band can require the selection of lower-level modules; these are either optional or recommended. (This is indicated in the block with the inclusion of this text.) If the addition of lower-level modules is required, the module description include Add in the text. Clicking on any Pink banded modules brings up the New icon and displays possible choices.
The CAN HAL Module must be configured by the user for the desired operation. The available configuration settings and defaults for all the user-accessible properties are given in the properties tab within the SSP configurator and are shown in the following tables for easy reference. Only properties that can be changed without causing conflicts are available for modification. Other properties are locked and not available for changes and are identified with a lock icon for the locked property in the Properties window in the ISDE. This approach simplifies the configuration process and makes it much less error-prone than previous manual approaches to configuration. The available configuration settings and defaults for all the user-accessible properties are given in the Properties tab within the SSP Configurator and are shown in the following tables for easy reference.
Configuration Settings for the CAN HAL Module on r_can
| ISDE Property | Value | Description |
|---|---|---|
| Parameter Checking | BSP, Enabled, Disabled Default: BSP | Enable or disable parameter error checking. |
| Name | g_can0 | Specify CAN Module instance name. |
| Channel | 0 | Specify if the CAN channel is to use 0 or 1 (S7G2 only). |
| Baud Rate Prescaler | 5 | Specify the baud rate prescaler (0-1023). See CAN Bit Rate Calculation. |
| Time Segment 1 | 4 Time Quanta thru 16 Time Quanta Default: 15 Time Quanta | Specify the time segment 1 value (4-16). See CAN Bit Rate Calculation. |
| Time Segment 2 | 2 Time Quanta thru 8 Time Quanta Default: 8 Time Quanta | Specify the time segment 2 value (2-8). See CAN Bit Rate Calculation. |
| Synchronization Jump Width | 1 Time Quanta thru 4 Time Quanta Default: 2 Time Quanta | Specify the Synchronization Jump Width value (1-4). See CAN Bit Rate Calculation. |
| Clock Source | PCLKB (S7G2 and S3A7 only), CAN MCLK Default: CAN MCLK | CAN clock source, CANMCLK or PCLKB (S7G2 and S3A7 only). |
| Callback | NULL | A user callback function can be registered in open. If this callback function is provided, it is called from the interrupt service routine (ISR) each time any interrupt occurs. Warning: Since the callback is called from an ISR, care should be taken not to use blocking calls or lengthy processing. Spending excessive time in an ISR can affect the responsiveness of the system. |
| Overwrite/Overrun Mode | Overwrite Mode, Overrun Mode Default: Overwrite Mode | Select whether receive mailbox will be overwritten or overrun if data is not read in time. |
| Standard or Extended ID Mode | Standard ID Mode, Extended ID Mode Default: Standard ID Mode | Select whether the driver will be using CAN standard or extended IDs. |
| Number of Mailboxes | 4, 8, 16, 32 Mailboxes Default: 32 Mailboxes | Select 4, 8, 16 or 32 mailboxes. |
| Mailbox 0-31 ID | 0-31 | Select the receive ID for mailbox 0, between 0 and 0x7ff when using standard IDs, between 0 and 0x1FFFFFFF when using extended IDs. Value is not used when the mailbox is set as transmit type. |
| Mailbox 0 Type | Receive Mailbox, Transmit Mailbox Default: Transmit Mailbox | Select whether the mailbox is used for receive or transmit. |
| Mailbox 1-31 Type | Receive Mailbox, Transmit Mailbox Default: Receive Mailbox | Select whether the mailbox is used for receive or transmit. |
| Mailbox 0 Frame Type | Data Mailbox, Remote Mailbox Default: Remote Mailbox | Select whether the mailbox is used to capture data frames or remote frames (receive only). |
| Mailbox 1-31 Frame Type | Data Mailbox, Remote Mailbox Default: Data Mailbox | Select whether the mailbox is used to capture data frames or remote frames (receive only). |
| Mailbox 0-3 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 0-3. See Setting the Mailbox Group Masks. |
| Mailbox 4-7 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 4-7. See Setting the Mailbox Group Masks. |
| Mailbox 8-11 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 8-11. See Setting the Mailbox Group Masks. |
| Mailbox 12-15 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 12-15. See Setting the Mailbox Group Masks. |
| Mailbox 16-19 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 16-19. See Setting the Mailbox Group Masks. |
| Mailbox 20-23 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 20-23. See Setting the Mailbox Group Masks. |
| Mailbox 24-27 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 24-27. See Setting the Mailbox Group Masks. |
| Mailbox 28-31 Group Mask | 0x1FFFFFFF | Select the Mask for mailboxes 28-31. See Setting the Mailbox Group Masks. |
| Error Interrupt Priority | Priority 0 (highest), Priority 1:14, Priority 15 (lowest - not valid if using ThreadX) Default: Priority 12 | Specify the error interrupt priority 0-15 (required). |
| Receive Mailbox Interrupt Priority | Priority 0 (highest), Priority 1:14, Priority 15 (lowest - not valid if using ThreadX) Default: Priority 12 | Specify the receive interrupt priority 0-15 (required). |
| Transmit Mailbox Interrupt Priority | Priority 0 (highest), Priority 1:14, Priority 15 (lowest - not valid if using ThreadX) Default: Priority 12 | Specify the transmit interrupt priority 0-15 (required). |
The CAN peripheral uses the CANMCLK (main-clock oscillator) or PCLKB (S7G2, S5D9, S5D5, S3A7 and S3A7 only) as its clock source (fCAN, CAN System Clock.) Using the PCLKB with the default of 60 MHz and the Synergy default, (S7G2 DK) CAN configuration will provide a CAN bit rate of 500 Kbit.
To set the PCLKB frequency, use the clock configurator in e2 studio. To change the clock frequency at run-time, use the CGC Interface. Refer to the CGC module guide for more information on configuring clocks.
The CAN peripheral module uses the pins on the MCU to communicate to external devices connected on the CAN bus. Under Peripherals, select CAN and then CAN0 for channel 0 or CAN1 (S7G2 and S3A7 only) for channel 1. The operation mode for the channel must be enabled and the CRXn and CTXn pins must be selected to match your PC board layout. The pin configurator sets appropriate CAN pin configuration in the pin_cfg field for the associated pin. The following table illustrates the method for selecting the pins within the SSP configuration window and the subsequent table illustrates an example selection for the CAN pins.
Pin Selection for the CAN HAL Module on r_ can
| Resource | ISDE Tab | Pin selection Sequence |
|---|---|---|
| CAN | Pins | Select Peripherals> CAN> CAN0 |
Pin Configuration Settings for the CAN HAL Module on r_ can
| Property | Value | Description |
|---|---|---|
| Operation Mode | Disabled, Enabled | Enable the mode to use CAN0. |
| CRX | None, P202, P402 Default: P402 | CAN0_CRX0. |
| CTX | None, P203 P401 Default: P401 | CAN0_CTX0. |
CAN Bit Rate Calculation
A time quanta (Tq) is one bit-time of the CAN communication clock, fCANCLK. This is not the CAN bit-time but the internal clock period of the CAN peripheral. The frequency is determined by the baud-rate prescaler value and the CAN source clock, fCAN (CANMCLK or PCLKB). One bit-time is divided into a number of time quanta, Tqtot. One time quantum is equal to the period of the fCANCLK. Each bitrate register is then given a certain number of Tq of the total of Tq that make up one CAN-bit period. The default ISDE bitrate setting (S7G2 DK template) is 500 Kbps for a fCAN at 60 MHz (using PCLKB.)
The formulas to calculate the bitrate register settings are as follows:
fCAN = (fPCLKB or fCANMCLK)
The baud-rate prescaler scales the CAN peripheral clock down.
fCANCLK = fCAN/ Baud Rate Prescaler = 60 MHz (default)/ 5(default) = 12 MHz
One time quantum is one clock period of the CAN clock.
Tqtot =1/fCANCLK
Tqtot is the total number of CAN peripheral clock cycles during one CAN bit time and is by the peripheral built by the sum of the "time segments" and "SS" which is always 1.
Tqtot = TSEG1 + TSEG2 + SS (TSEG1 must be > TSEG2) = 15 + 8 + 1 = 24 (default)
The bitrate is then:
Bitrate = fCANCLK/Tqtot = 12 MHz / 24 = 500 Kbps
Important notes:
Configurator sample values for different CAN bit-rate
| fCAN (either PCLKB or CAN MCLK) | Baud Rate Prescalar | fCANCLK = fCAN / Baud Rate Prescalar | Time Segment 1 (TSEG1) | Time Segment 2 (TSEG2) | Synchronization Jump Width (SS) | Tqtot = TSEG1 + TSEG2 +SS | Bitrate = fCA NCLK / Tqtot |
|---|---|---|---|---|---|---|---|
| 240 | 10 | 24 | 15 | 8 | 1 | 24 | 1 Mbps |
| 60 | 5 | 12 | 15 | 8 | 1 | 24 | 500 kbps |
| 240 | 48 | 5 | 16 | 2 | 2 | 20 | 250 kbps |
| 240 | 96 | 2.5 | 16 | 2 | 2 | 20 | 125 kbps |
Setting the Mailbox Group Masks
There are 8 mailbox group-masks, one for each group of 4 mailboxes. These masks allow the mailboxes to be configured to receive more than one ID. If the mask is all ones (0x7ff for standard IDs or 0x1FFFFFFF for extended ID) the mailboxes within the group do not mask any bits of the ID, requiring all bits of the mailbox ID to match the mailbox ID before a message is captured. If any bits of the mask are set to zero, those bits will not be necessary to match the same bits of the mailbox ID. For example, if Mailbox ID 1 is set to 0x7ff and Mailbox 0-3 Group Mask is set to 0x7ff, mailbox 1 will only capture messages with the ID of 0x7ff. If the mailbox 0-3 group mask is set to 0x7fe, mailbox 1 will still capture messages with IDs of 0x7f but will also capture messages with IDs of 0x7fe.
A CAN application requires a minimum of two nodes to demonstrate CAN communication. One node can be a transmitter, while the other can be a receiver (or both can behave as transmitter and receiver.)
The typical steps in using the CAN HAL Module in an application are:
These common steps are illustrated in a typical operational flow diagram in the following figure: