1.0
	- initial customer SW release
1.01
	- calibration table, reference value update
1.1
	- FW display in GUI
	- OWI protocol adjustamnet to FW 4.14
	- Caption change from Sevilla to ZSSC3240
	- Consistent assignment of coefficients NVM <-> calibration tab
	- ADC offset indication changed
	- Parameter value update also after reprogramming registers
1.2
	- Measuremnet date display and log for 24bit resolution/display have lost LSBs -> Buf fix
	- AZ-assignment corrected
	- IC self diagnostic application simplified
	- Button for HV-supply added, e.g. for 0..10V analog voltage output
1.3
	- New CB communication module (improved COM port detection/connectivity/log)
	- Adjustments in spi_send/spi_receive functions
	- Cyclic sequences parameter/ write to NVM buttom functionality
	- Option included for calibration with full cycle measurement commands
	- In cyclic mode the NVM is not read any more, after opening the GUI
	- Parameter 'update rate / cycle period' shifted to Cyclic Operation Sequence
	- Status check now with only reading sequence
	- Menu->Interface->Setup is now applicable
1.4
	- Raw measurmnet duration adjuatment, avodance of BUSY state in status byte
	- Leaving cyclic mode for OWI without reset
	- Interface speed settings are monitored and shown also when  opening IF setup window
	- IF speed setting is visible in teh main window
	- If fm_ver == 'V4.12' -> OWI speed adjustment is FW-sensitive
	- Implementation of the old boards.py module / receive_spi (deleted addr-parameter)
	- ADC display control extended to a minimum of 12Bit
	- Interface setup -> threshold limitation included
	- Closing/reopening COM port: SW keeps the IF
1.41
	- Cyclic Mode: digital captureing measurement results works with SPI/I2C/OWI
	- Corrected measurement now also in %/C available
	- Measuremnet Control -> Meas. Timer -> delay time between measurements adjustable
	- Thresholds input limitation included
	- Load/Save NVM configuration mapped to .nvm extension, added a save dialog
	- Cyclic output in default mode:cyclic-> polling provides juts teh defined DAC output -> OK

2.0 - Silicon B Release
	- Parameter captions in GUI adjusted
	- ADC-offset shift values set to real silicon behaviour
	- IF-setup: switching intface bug fix
	- Register 0x1D assigned to B-silicon structure: MSBs of SENS_SHIFT[15:8], MSBs of T_SHIFT[7:0]
	- Calibration pints positions graph: reference calibration points are shown as it is defined in the calibration point table
	- Cyclic mode & SPI application caused SW crash -> bug fixed
	- IDT internal register: clock gationg bit assignment corrected
2.1 	
	- Interface detection faulty in certain settings -> fixed
	- Diagnostic/Terminal UI adjustes
	- ADC Self-Diagnostic measurement added
	- Sensor Check Selection was not working with SPI -> fixed
	- CB FW v4.18 compatibility checked -> available
	- Raw measurement options extended with only sensor/temperature measurements
	- NVM content appears now always as a 4-digit data
	- Quit-button functionality added
	- NVM laod/save dialog exceptions included for unintended user input
	- y-axis caption optimzed for according measurement types
2.11
	- Sensor chek section updated to full on-chip diagnostic section
2.12
	- Fixes in 2.11 corrupted DAC-diagnostic -> fixed
2.13	
	- On-Chip Diagnostics -> SSC calculation checkbox gets unchecked when applying sensor check -> fixed
	- On-Chip Diagnostics -> Text-INP short not applied -> fixed
	- If On-Chip Diagnostics changes the register value -> automatic IC-reset included
	- Text-INP-short mask wrong -> fixed

3.0 - Silicon C Release
	- New Aout-options included (Vout + OWI2) 
	- Traceability included
	- DAC-Output calibration data displayed, if available
	- Parameter renamed in register 0x03 (SSF1): 'OWI Appl. Case' ->  'OWI SU Case'
3.01 
	- Additional button -> Start Cyclic Mode
	- Changed captions: Enter Command Mode -> Start Command Mode; Enter Sleep Mode -> Start Sleep Mode
	- First polling after reset in cyclic mode provides zeros as measurement result -> not displayed any more in graph
3.02
	- DAC-Diagnostic -> V_DACx0_AOUT[V] -> rounded
	- Labels changed, typos fixed
3.1	
	- MCB functionality included
	- Renesas logo added
	- Parameter caption chnge: IN OFFSET -> IOffsC
	- Diagnostic/Cyclic Configurtaion...-tab -> Cyclic Operation Sequence adjusted to synchronize SM/AZSM and TM/AZTM
3.2 
	- Bug in 'Load NVM Config' -> fixed
	- MCS: DUTs with BUSY status displayed and can be included for calicbration optionally
	- MCS: IC-Status automaticall updated by switching teh focussed DUT
3.21	
	- MCS -> 'n.C.' status adjusted to low case 
	- MCS -> DUT # now aligned to center
	- Diagnostic/Cyclic Configurtaion...-tab -> Cyclic Operation Sequence adjusted to synchronize 1st slot SM/AZSM and TM/AZTM
	- additional SW rev.3.22A -> Arial font used, smaller size, bigger tables for high resolution displays which distort teh GUI appearance
3.3
	- Twoscomplement conversion bug fix
	- Terminal -> read command function reduced to essential
	- EVSW status check -> only read seqeunce, no command prior to it (identification cyclic mode)
	- AFE configurator for ratiometic and absolute voltage sensor applications (new implementation in config_calc -> kann noch berraschungen beherbergen)
	- Highlightning changed rows in the NVM table -> bug fix
	- Diagnostic check boxes signals processing -> adjusted to common processing
	- NVM tabel changes highlight teh according parameter, except diogntistc check boxes
	- Interface settings saved when port closed via button
	- Terminal und Diagnostic buttons disables when power off or communication port disconnected 
	- Load/save NVM configuration: file activity flag removed, inherently applied by dialog
	- Trace data excpections included
	- Logos/icons/graphic managed in qressources
	- Changes of single registers highlight the affected parameters
3.31 	
	- Renesas task icon added
	- Minor OWI bug fix
	- NVM writing restriction added
	- Calibration extended with s-shape compensation option
	- Update of the calibration.dll
	- TM/AZTM pause length -> GUI bug fix
	- Icon for Interface Setup Configuration added
3.4 
	- Mass Calibration System SW extended for multi MCBs usage
3.41
	- Product check bug fix
3.42
	- MCB SW customization (status reuqest initial start)
	- OWI master option included / hidden in official release
3.43
	- Additional button (single command section): OWI Start up triggered by VDD rising edge -> within teh 50ms window
3.44
	- Product ID extension for wafer dies
	- Minor AFE calculator bug fix
3.45	
	- Communication script load option added: Diagnostic / Cyclic Configuration / Command Section -> Terminal
3.46
	- AFE calculator bug fix
3.47
	- Voltage output 0..10 in combination with OWI (and master board) implemented
3.5
	- Analog output calibration option for Vout/Current Loop included -> calibration tab
3.51
	- Calibration options included for coefficient variation (when small bridge TC is used for T-measurement). It applied autmatically in the DLL 
	-> calibration tab
	
3.52
	- DLL changes (Temperature range : -5000..5000C ; Variation of initial conditions for coefficients calculation)