Production Line Tool v5.0
The DA1470x Production Line Tool Software Package
Loading...
Searching...
No Matches
Public Attributes | List of all members
__pltd_ble_test_rx_sens Struct Reference

BLE tester measurement settings for the RX sensitivity measurements common to all DUTs. More...

#include <prod_line_tool_dll.h>

Public Attributes

bool en
 
char name [TEST_NAME_STR_SIZE]
 
uint32_t freq
 
uint8_t pattern
 
uint16_t spacing
 
uint16_t num_of_pkts
 
float tx_power
 
bool dirty
 
bool crc_state
 
float per_lim
 
float rssi_lim
 

Detailed Description

BLE tester measurement settings for the RX sensitivity measurements common to all DUTs.

Definition at line 728 of file prod_line_tool_dll.h.

Member Data Documentation

◆ crc_state

bool __pltd_ble_test_rx_sens::crc_state

ON=alternate CRC state from correct to incorrect.

Definition at line 738 of file prod_line_tool_dll.h.

◆ dirty

bool __pltd_ble_test_rx_sens::dirty

When ON, the packet generator uses the dirty table from the selected script LESS test.

Definition at line 737 of file prod_line_tool_dll.h.

◆ en

bool __pltd_ble_test_rx_sens::en

Enable or disable the BLE tester RX sensitivity measurements.

Definition at line 730 of file prod_line_tool_dll.h.

◆ freq

uint32_t __pltd_ble_test_rx_sens::freq

The frequency in MHz that the measurements will be performed.

Definition at line 732 of file prod_line_tool_dll.h.

◆ name

char __pltd_ble_test_rx_sens::name[TEST_NAME_STR_SIZE]

The name of each test.

Definition at line 731 of file prod_line_tool_dll.h.

◆ num_of_pkts

uint16_t __pltd_ble_test_rx_sens::num_of_pkts

The number of packets to transmit. 0=continuous. 1-65535=Fixed umber of packets to sent.

Definition at line 735 of file prod_line_tool_dll.h.

◆ pattern

uint8_t __pltd_ble_test_rx_sens::pattern

The pattern of the TX data. 0=PRBS9, 1=10101010, 2=11110000.

Definition at line 733 of file prod_line_tool_dll.h.

◆ per_lim

float __pltd_ble_test_rx_sens::per_lim

PER limit percentage for the RF RSSI test.

Definition at line 739 of file prod_line_tool_dll.h.

◆ rssi_lim

float __pltd_ble_test_rx_sens::rssi_lim

RSSI limit for the BLE tester sensitivity tests.

Definition at line 740 of file prod_line_tool_dll.h.

◆ spacing

uint16_t __pltd_ble_test_rx_sens::spacing

1us steps of packet spacing. 625us to 65535us.

Definition at line 734 of file prod_line_tool_dll.h.

◆ tx_power

float __pltd_ble_test_rx_sens::tx_power

The BLE instrument transmitted power level from 0.0 to -90.0dBm.

Definition at line 736 of file prod_line_tool_dll.h.


The documentation for this struct was generated from the following file: