Production Line Tool v5.0
The DA1470x Production Line Tool Software Package
Loading...
Searching...
No Matches
Public Attributes | List of all members
__pltd_ammeter_params Struct Reference

Ammeter test settings and limits for testing current. More...

#include <prod_line_tool_dll.h>

Public Attributes

bool en
 
bool single_dut
 
_sleep_modes mode
 
uint32_t sleep_time
 
uint32_t wait_time
 
float shunt_res
 
double range
 
double resolution
 
uint32_t samples
 
double upper_lim
 
double low_lim
 
char gen_cmd [PLTD_INSTR_MAX_STR_SIZE]
 

Detailed Description

Ammeter test settings and limits for testing current.

Definition at line 761 of file prod_line_tool_dll.h.

Member Data Documentation

◆ en

bool __pltd_ammeter_params::en

Enable or disable the current measurement test.

Definition at line 763 of file prod_line_tool_dll.h.

◆ gen_cmd

char __pltd_ammeter_params::gen_cmd[PLTD_INSTR_MAX_STR_SIZE]

Generic SCPI command that will be passed to the instrument.

Definition at line 774 of file prod_line_tool_dll.h.

◆ low_lim

double __pltd_ammeter_params::low_lim

The value of the low current limit for PASS/FAIL criteria.

Definition at line 773 of file prod_line_tool_dll.h.

◆ mode

_sleep_modes __pltd_ammeter_params::mode

Select the sleep mode to be used during current measurement, taken from /ref __sleep_modes.

Definition at line 765 of file prod_line_tool_dll.h.

◆ range

double __pltd_ammeter_params::range

The range that the instrument will operate in Ampere units.

Definition at line 769 of file prod_line_tool_dll.h.

◆ resolution

double __pltd_ammeter_params::resolution

The resolution that the instrument will operate in Ampere units.

Definition at line 770 of file prod_line_tool_dll.h.

◆ samples

uint32_t __pltd_ammeter_params::samples

The number of samples/measurements that the instrument will take and average.

Definition at line 771 of file prod_line_tool_dll.h.

◆ shunt_res

float __pltd_ammeter_params::shunt_res

The value of the external shunt resistor used for the ammeter.

Definition at line 768 of file prod_line_tool_dll.h.

◆ single_dut

bool __pltd_ammeter_params::single_dut

Measure current one device at the time. PLT will switch off all DUTs and power-on one by one. It will then measure the current of the single active DUT.

Definition at line 764 of file prod_line_tool_dll.h.

◆ sleep_time

uint32_t __pltd_ammeter_params::sleep_time

How much time the DUT will be set to extended sleep mode. This value sets a timer in the production test firmware, which wakes up the DUT.

Definition at line 766 of file prod_line_tool_dll.h.

◆ upper_lim

double __pltd_ammeter_params::upper_lim

The value of the upper current limit for PASS/FAIL criteria.

Definition at line 772 of file prod_line_tool_dll.h.

◆ wait_time

uint32_t __pltd_ammeter_params::wait_time

How much time the PLT will wait before taking a current measurement, after it instructed the DUT to go to a specific state (e.g. idle, extended sleep, deep sleep).

Definition at line 767 of file prod_line_tool_dll.h.


The documentation for this struct was generated from the following file: