Production Line Tool v5.0
The DA1470x Production Line Tool Software Package
Loading...
Searching...
No Matches
Public Attributes | List of all members
__pltd_ble_test_mod_idx Struct Reference

BLE tester measurement settings for the TX modulation index measurements common to all DUTs. More...

#include <prod_line_tool_dll.h>

Public Attributes

bool en
 
char name [TEST_NAME_STR_SIZE]
 
uint32_t freq
 
uint8_t tx_pwr_range
 
_pdll_tx_pwr_lvl tx_pwr
 
uint32_t f1_min_limit
 
uint32_t f1_max_limit
 
uint32_t f2_max_limit
 
float f1f2_ratio_limit
 

Detailed Description

BLE tester measurement settings for the TX modulation index measurements common to all DUTs.

Definition at line 714 of file prod_line_tool_dll.h.

Member Data Documentation

◆ en

bool __pltd_ble_test_mod_idx::en

Enable or disable the BLE tester TX modulation index measurements.

Definition at line 716 of file prod_line_tool_dll.h.

◆ f1_max_limit

uint32_t __pltd_ble_test_mod_idx::f1_max_limit

The F1 maximum average limit in KHz for the TX modulation index pass/fail test criteria.

Definition at line 722 of file prod_line_tool_dll.h.

◆ f1_min_limit

uint32_t __pltd_ble_test_mod_idx::f1_min_limit

The F1 minimum average limit in KHz for the TX modulation index pass/fail test criteria.

Definition at line 721 of file prod_line_tool_dll.h.

◆ f1f2_ratio_limit

float __pltd_ble_test_mod_idx::f1f2_ratio_limit

The F1/F2 maximum average ratio limit for the TX modulation index pass/fail test criteria.

Definition at line 724 of file prod_line_tool_dll.h.

◆ f2_max_limit

uint32_t __pltd_ble_test_mod_idx::f2_max_limit

The F2 maximum limit in KHz for the TX modulation index pass/fail test criteria.

Definition at line 723 of file prod_line_tool_dll.h.

◆ freq

uint32_t __pltd_ble_test_mod_idx::freq

The frequency in MHz that the measurements will be performed.

Definition at line 718 of file prod_line_tool_dll.h.

◆ name

char __pltd_ble_test_mod_idx::name[TEST_NAME_STR_SIZE]

The name of each test.

Definition at line 717 of file prod_line_tool_dll.h.

◆ tx_pwr

_pdll_tx_pwr_lvl __pltd_ble_test_mod_idx::tx_pwr

Set the TX power level of the device under test. Values from /ref __pdll_tx_pwr_lvl.

Definition at line 720 of file prod_line_tool_dll.h.

◆ tx_pwr_range

uint8_t __pltd_ble_test_mod_idx::tx_pwr_range

Set the instrument TX input power range. Values from /ref __ble_instr_pwr_range.

Definition at line 719 of file prod_line_tool_dll.h.